Zhao H

Qingdao University of Science and Technology

2
Publications
23
h-index
(1,887 citations, 79 total works)

Research Topics

biodegradable polymer synthesis and properties (18)Polymer Foaming and Composites (14)Electrospun Nanofibers in Biomedical Applications (8)Surface Modification and Superhydrophobicity (6)Additive Manufacturing and 3D Printing Technologies (6)

Alpha-gal Syndrome Publications

Structure and properties of the acellular porcine cornea irradiated with Co-γ and electron beam and its histocompatibility.

Li Q, Sun Y, Zhao H, Zhang F, Guo Y, et al.
Journal of biomedical materials research. Part A •

Acellular porcine cornea (APC) has been used in corneal transplantation and treatment of the corneal diseases. Sterilization is a key step before the application of graft, and irradiation is one of the most commonly used methods. In this paper, APC was prepared by the physical freeze-thawing combined with biological enzymes, and the effects of the electron beam (E-beam) and cobalt 60 (Co-γ) at the dose of 15 kGy on the physicochemical properties, structure, immunogenicity, and biocompatibility of the APC were investigated. After decellularization, the residual DNA was 20.86 ± 1.02 ng/mg, and the α-Gal clearance rate was more than 99%. Irradiation, especially the Co-γ, reduced the cornea's transmittance, elastic modulus, enzymatic hydrolysis rate, swelling ratio, and cross-linking degree. Meanwhile, the diameter and spacing of the collagen fibers increased. In the rat subcutaneous implantation, many inflammatory cells appeared in the unirradiated APC, while the irradiated had good histocompatibility, but the degradation was faster. The lamellar keratoplasty in rabbits indicated that compared to the E-beam, the Co-γ damaged the chemical bond of collagen to a larger extent, reduced the content of GAGs, and prolonged the complete epithelization of the grafts. The corneal edema was more serious within 1 month after the surgery. After 2 months, the thickness of the APC with the two irradiation methods tended to be stable, but that in the Co-γ group became thinner. The pathological results showed that the collagen structure was looser and the pores were larger, indicating the Co-γ had a more extensive effect on the APC than the E-beam at 15 kGy.

Structure and properties of the acellular porcine cornea irradiated with electron beam and its in-situ implantation.

Li Q, Sun Y, Zhao H, Gao Z, Zhai D
Journal of biomedical materials research. Part B, Applied biomaterials •

Different sterilization doses of the electron beam (E-beam) will change the properties of biomaterials and affect their clinical application. Acellular porcine cornea (APC) is a promising corneal substitute to alleviate the shortage of corneal resources. The residual DNA was significantly reduced to 18.50 ± 3.19 ng/mg, and the clearance rate of α-Gal was close to 100% after the treatment with freezing-thawing combined enzyme, indicating that the decellularization was effective. The effects of different E-beam doses at 0, 2, 8, 15, and 25 kGy on the APC were studied. With the increase in irradiation dose, the transmittance, tensile strength, and swelling ratio of APC gradually decreased, but the resistance to enzymatic degradation was stronger than that of non-irradiated APC, especially at 8 kGy. The structure of APC was denser after irradiation, but the dose of 25 kGy could cause partial collagen fiber fracture and increase the pore size. The cell viability of the APC irradiated by 15 and 25 kGy were greater than 80%. After the implantation in rabbit corneas, there was no obvious neovascularization and inflammation, but the dose of 25 kGy had a more destructive effect on the chemical bonds of collagen, which made the APC easier to be degraded. The thickness of APC in the 25 kGy group was thinner than that in the 15 kGy group 1 year after surgery, and the epithelium grew more slowly, so the E-beam dose of 15 kGy might be more suitable for the sterilization of APC.