Seoul National University Children's Hospital

healthcare📍 Seoul, South Korea
2
Alpha-gal Syndrome Publications
2
Alpha-gal Syndrome Researchers

Associated Institutions

Seoul National University Hospital
parent

Publications

Mid-term outcomes of the Pulsta transcatheter pulmonary valve for the native right ventricular outflow tract.

Lee SY, Kim GB, Kim SH, Jang SI, Choi JY, et al.
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions •

The aim of this study is to present the mid-term outcomes of Pulsta valve. The Pulsta valve is a Self-expandable knitted nitinol-wire stent mounted with a treated tri-leaflet α-Gal-free porcine pericardial valve for percutaneous pulmonary valve implantation (PPVI) in patients with native right ventricular outflow tract (RVOT) lesions. A multi-center clinical trial using Pulsta valve® was designed for patients with severe pulmonary regurgitation (PR) in the native RVOT in multiple centers in South Korea and 25 patients were enrolled. Before PPVI, severe PR (mean PR fraction: 45.5 ± 6.9%) and enlarged RV volume (mean indexed RV end-diastolic volume; 169.7 ± 13.0 ml/m ) was present. The mean age was 21.6 ± 6.6 years old. All patients were successfully implanted with 26, 28, or 32 mm diameter of Pulsta valve loaded on the 18 or 20 French delivery catheters. At 6 months follow up, indexed RV end-diastolic volume was decreased to 126.9 ± 16.9 ml/m . At mean 33.1 ± 14.3 months follow-up, the mean value of mean pressure gradient in Pulsta valve was 6.5 ± 3.0 mmhg without significant PR. There was no serious device-related adverse event. A multi-center clinical trial was completed successfully with planned Pulsta valve implantation and demonstrated good mid-term effectiveness without device-related serious adverse events.

Successful Feasibility Human Trial of a New Self-Expandable Percutaneous Pulmonary Valve (Pulsta Valve) Implantation Using Knitted Nitinol Wire Backbone and Trileaflet α-Gal-Free Porcine Pericardial Valve in the Native Right Ventricular Outflow Tract.

Kim GB, Song MK, Bae EJ, Park EA, Lee W, et al.
Circulation. Cardiovascular interventions •

Self-expandable percutaneous pulmonary valve implantation (PPVI) for native right ventricular outflow tract lesions is still in the clinical trial phase. The aim of this study is to present the result of feasibility study of a novel self-expandable knitted nitinol wire stent mounted with a treated trileaflet α-Gal-free porcine pericardial valve for PPVI. A feasibility study using Pulsta valve (TaeWoong Medical Co, Gyeonggi-do, South Korea) was designed for patients with severe pulmonary regurgitation in the native right ventricular outflow tract, and 6-month follow-up outcomes were reviewed. Ten tetralogy of Fallot patients were enrolled. Before PPVI, severe pulmonary regurgitation (mean pulmonary regurgitation fraction, 45.5%±7.2%; range, 34.9%-56%) and enlarged right ventricular volume (mean indexed right ventricular end-diastolic volume, 176.7±14.3 mL/m; range, 158.9-205.9 mL/m) were present. The median age at PPVI was 21.7±6.5 years (range, 13-36 years). Five patients were successfully implanted with 28 mm and the other 5 with 26 mm valves loaded on the 18F delivery cable. No significant periprocedural complications were noted in any patient. At the 6-month follow-up, indexed right ventricular end-diastolic volume was dramatically decreased to 126.3±20.3 mL/m (range, 99-164.2 mL/m), and the mean value of peak instantaneous pressure gradient between the right ventricle and the pulmonary artery decreased from 6.8±3.5 mm Hg (range, 2-12 mm Hg) before PPVI to 5.7±6.7 mm Hg (range, 2-12 mm Hg) without significant pulmonary regurgitation. There was no adverse event associated with the valve. A feasibility study of the Pulsta valve for native right ventricular outflow tract lesions was completed successfully with planned Pulsta valve implantation and demonstrated good short-term effectiveness without serious adverse events. URL: https://www.clinicaltrials.gov. Unique identifier: NCT02555319.