Centre François Baclesse

nonprofit📍 Esch-sur-Alzette, Luxembourg
2
Alpha-gal Syndrome Publications
2
Alpha-gal Syndrome Researchers

Publications

Case Report About Fatal or Near-Fatal Hypersensitivity Reactions to Cetuximab: Anticetuximab IgE as a Valuable Screening Test.

Dupont B, Mariotte D, Moldovan C, Grellard JM, Vergnaud MC, et al.
Clinical Medicine Insights. Oncology •

Hypersensitivity reactions are a classic side effect of cetuximab. We report the cases of three patients who developed life-threatening hypersensitivity to cetuximab, which could have been predicted by assessing the concentration of serum anticetuximab immunoglobulin (Ig)E. The anticetuximab IgE concentration could be an interesting test to predict which patients are at risk of experiencing severe hypersensitivity reactions to cetuximab.

Anti-cetuximab IgE ELISA for identification of patients at a high risk of cetuximab-induced anaphylaxis.

Mariotte D, Dupont B, Gervais R, Galais MP, Laroche D, et al.
mAbs •

Cetuximab, a chimeric mouse-human IgG1 monoclonal antibody against the epidermal growth factor receptor, has proven effective in the treatment of metastatic colorectal cancer and squamous cell carcinoma of the head and neck. However, a high incidence of immediate hypersensitivity reactions (HSR) to cetuximab after the first infusion has been observed. We have developed a test for identification of patients likely to show treatment-related HSR to cetuximab. An enzyme-linked immunosorbent assay (ELISA) for detecting anti-cetuximab IgEs was developed and tested on serum samples collected from cancer patients before start of cetuximab treatment, and from healthy blood donors. Similar levels of anti-cetuximab IgE were detected in pre-treatment patient sera (24/92, 26.1%) and sera from healthy blood donors (33/117, 28.2%). HSR were observed in 14 out of the 92 patients (15.2%), and 8 of these (57.1%) were grade 3-4. Anti-cetuximab IgEs were detected in 7/8 of the patients (87.5%) with severe HSRs as compared with 14/78 patients (17.9%) with no HSR (p=0.0002). Predictive value of the anti-cetuximab IgE test for HSR events of grades 3-4 was calculated using Receiver Operating Characteristics analysis. With a cut-off value of 29 arbitrary units for the anti-cetuximab IgE, the ELISA test showed a sensitivity of 87.5%, specificity of 82.1%, positive predictive value of 33.3% and negative predictive value of 98.5%. Anti-cetuximab IgE ELISA detection could be a valuable tool to help the physician anticipate an anaphylaxis episode following cetuximab infusion and opt for a suitable alternative treatment.